Search

7559A0000U BECKETT PRIMARY CONTROL

Manufacturer: Beckett
SKU: BECKETT:7559A0000U
Product Availability: 1
$240.94
This product must be purchased in increments of 1
i h

⚑ Beckett 7559A0000U GeniSys 7559 24V Oil Burner Control – 15 Sec Lockout

πŸ“ Product Overview

The Beckett 7559A0000U GeniSys 7559 is a 24 VDC primary safety control designed for heavy-duty oil burners in high-moisture and industrial environments. Engineered for pressure washers, road stripers, crack sealers, hot patchers, asphalt distributors, and similar equipment, this epoxy-potted control manages the burner motor, igniter, and optional solenoid valve with interrupted ignition and a 15-second lockout for enhanced safety.

Compatible with the GeniSys CAD Cell Flame Detector Kit 7006U (sold separately) and programmable via the GeniSys Contractor Tool 52082 (sold separately), this control stores the last 15 burner cycles for diagnostics and maintenance.


⚠️ Important Update – Beckett Control PackagesΒ 

Beckett has stopped including completion kits (wire leads, wire nuts, and adapters) with the following control models:

7505 β€’ 7575 β€’ 7580 β€’ 7556 β€’ 7559

What’s Changed?

  • Wire Leads, Wire Nuts, and Adapters are no longer included

  • Customers must purchase these components separately if needed

Need the Complete Setup?

  • 7505 / 7575 / 7580 β†’ Order Kit: 7505WSKU

  • 7556 / 7559 β†’ Order Kit: 7556WSKU

πŸ‘‰ Be sure to add the correct kit if your installation requires these items


βœ… Key Features & Benefits

βœ”οΈ 24 VDC Primary Safety Control – Reliable control of oil burner motor, igniter, and optional solenoid valve
βœ”οΈ Epoxy-Potted Design – Provides excellent moisture resistance for harsh environments
βœ”οΈ Interrupted / Intermittent Ignition – Ensures safe burner operation with 15-second lockout
βœ”οΈ Programmable Pre- and Post-Purge – Optimizes chamber cooling and system efficiency using the GeniSys Contractor Tool 52082 (sold separately)
βœ”οΈ Diagnostic Memory – Stores last 15 burner cycles for troubleshooting
βœ”οΈ High Ambient Temperature Rating – Operates from -40Β°F to 160Β°F
βœ”οΈ Alarm Output – Visual or audible indication of flame failure or lockout
βœ”οΈ Welded Relay Protection – Redundant motor relays enhance reliability
βœ”οΈ Fused Protection – Protects motor, igniter, valve, and control circuits
βœ”οΈ Relight Function – Automatically attempts to reestablish flame if lockout occurs


⚑ Input Ratings

ParameterSpecification
Voltage 21.6–30 VDC
Current 0.3 A

⚑ Output Ratings

OutputSpecification
Motor 10 FLA / 50 LRA
Igniter 3 A
Solenoid Valve 1 A
Lockout Alarm 1 A
Enable Load 0.02 A

πŸ“Š Specifications

CategorySpecification
Manufacturer Beckett
Model 7559A0000U
Series GeniSys 7559
Lockout Time 15 Seconds
Ignition Type Interrupted / Intermittent Duty
Flame Sensor GeniSys CAD Cell Kit 7006U (sold separately)
Programming Tool GeniSys Contractor Tool 52082 (sold separately)
Cycle Memory Stores last 15 burner cycles
Ambient Temperature -40Β°F to 160Β°F

⚠️ Common Symptoms When Replacement Is Needed

  • Burner fails to start or ignite

  • Frequent flame failure lockouts

  • Motor or igniter does not respond to control signals

  • Alarm output triggers repeatedly

  • Erratic burner operation due to moisture or environmental exposure


❓ Frequently Asked Questions (FAQ)

Q: What equipment is the 7559A0000U used on?
A: Ideal for pressure washers, road stripers, crack sealers, hot patchers, asphalt distributors, and similar oil-fired equipment.

Q: Can it operate in high-moisture environments?
A: Yes β€” the epoxy-potted housing provides excellent moisture resistance.

Q: What ignition types does it support?
A: Interrupted or intermittent duty ignition with a 15-second lockout time.

Q: Can I program pre- and post-purge timing?
A: Yes β€” using the GeniSys Contractor Tool 52082 (sold separately).

Q: How does the diagnostic memory work?
A: Stores the last 15 cycles for easier troubleshooting and performance monitoring.

Q: Do I need additional kits or accessories?
A: Yes β€” the GeniSys CAD Cell Flame Detector Kit 7006U (sold separately) is required for full burner control.


πŸ›’ Shopping Tips

  • Pair with GeniSys CAD Cell Flame Detector Kit 7006U (sold separately) for full burner control

  • Verify input voltage (21.6–30 VDC) and ambient temperature range for your equipment

  • Use genuine Beckett GeniSys controls to ensure safe, reliable operation

  • Keep diagnostic and programming tools on hand for maintenance and adjustments

Products specifications
Manufacturer Beckett
Customers who bought this item also bought
Picture of 5270005U BECKETT 12VDC IGNITOR ONLY FOR ADC AND SDC OIL BURNERS

5270005U BECKETT 12VDC IGNITOR ONLY FOR ADC AND SDC OIL BURNERS

BECKETT:5270005U
SKU: BECKETT:5270005U
$196.42
Product Availability: 7
Picture of 5272005U BECKETT UNIT PACK 24VDC IGNITER

5272005U BECKETT UNIT PACK 24VDC IGNITER

BECKETT:5272005U
SKU: BECKETT:5272005U
$203.07
Product Availability: 1