Search

R2006600 LAARS TEMPERATURE CONTROL SENSOR PROBE

Manufacturer: Laars
SKU: LAARS:R2006600
Product Availability: Out of stock
$271.17
This product must be purchased in increments of 1
i h

R2006600 Laars Temperature Control Sensor Probe

The R2006600 Laars Temperature Control Sensor Probe is a reliable PTC silicon temperature sensor designed for accurate temperature monitoring in HVAC and refrigeration systems. Cross-referenced to Johnson Controls A99BC-300, this passive sensor delivers precise readings, excellent durability, and dependable performance across a wide operating temperature range.

With a high-temperature silicon cable and splashproof construction, this sensor is ideal for demanding commercial and industrial environments.


✅ Key Features

  • ✅ Genuine Laars temperature control sensor probe

  • ✅ Cross-reference to Johnson Controls A99BC-300

  • ✅ Passive PTC (Positive Temperature Coefficient) silicon sensor

  • ✅ Splashproof design for HVAC and refrigeration environments

  • ✅ Wide operating temperature range for versatile applications

  • ✅ High-temperature silicon cable for long service life

  • ✅ Accurate and stable resistance characteristics


📋 Specifications

SpecificationDetails
Laars Part Number R2006600
Johnson Controls Model A99BC-300
Sensor Type PTC Silicon Temperature Sensor
Cable Length 9-3/4 ft (3 m)
Temperature Range -40 to 248°F (-40 to 120°C)
Reference Resistance 1,035 Ω at 77°F (25°C)
Accuracy ±0.9°F (±0.5°C) between 5–167°F (-15–75°C)
Cable Type High-Temperature Silicon
Construction Splashproof

🔄 Cross Reference Table

BrandPart Number
Laars R2006600
Johnson Controls A99BC-300

⚠️ Common Symptoms Indicating Replacement

  • Inaccurate or unstable temperature readings

  • Unit short-cycling or failing to maintain setpoint

  • Defrost cycle not terminating correctly

  • Condenser fan not cycling as designed

  • Sensor damage, corrosion, or cable deterioration


❓ Frequently Asked Questions (FAQ)

Q: Is this sensor active or passive?
A: This is a passive PTC sensor and does not require external power.

Q: Can this be used in refrigeration applications?
A: Yes. It is designed for refrigeration, HVAC, and process temperature sensing.

Q: Is the sensor suitable for outdoor use?
A: Yes, it can be used for outdoor air sensing when properly installed.

Q: Does this replace Johnson Controls A99BC-300?
A: Yes, the R2006600 is a direct cross-reference replacement.


🛒 Shopping Tips

  • Confirm resistance and temperature range match your control requirements.

  • Verify cable length is sufficient for your installation.

  • Ensure proper mounting for accurate temperature sensing.

  • Avoid sharp bends or pinching the sensor cable during installation.

Products specifications
Manufacturer Laars